Homeowner & Landlord Electrical Guide

What Happens if Your Property Fails an EICR?

Getting an ‘Unsatisfactory’ result on an Electrical Installation Condition Report (EICR) is more common than most people think—and it doesn’t mean your power gets cut off or that you have to pay for a full retest from scratch. Here is a plain-English breakdown of why reports fail, the 28-day rule for landlords, and how the sign-off process actually works.

The Short Answer

  • FAILS Any single C1 (immediate danger), C2 (potentially dangerous), or FI (further investigation needed) code automatically makes the whole report Unsatisfactory.
  • 28 DAYS For rented homes, landlords legally have 28 days (or less if specified) to get C1, C2, and FI faults repaired by a qualified electrician.
  • SIGN-OFF You do not need to pay for a brand-new EICR once repairs are done. Your electrician issues a certificate for the repair work and written confirmation that the installation is now safe.

What Does an ‘Unsatisfactory’ EICR Actually Mean?

In trade terms, there is no certificate with “PASS” or “FAIL” stamped across the top. Instead, an Electrical Installation Condition Report comes back as either Satisfactory or Unsatisfactory.

As electricians, we don’t get to pick and choose based on a gut feeling. Every observation we find during testing is given a classification code. If your property picks up even a single C1, C2, or FI code, the software and the wiring regulations automatically mark the entire report as Unsatisfactory.

Code C1 Triggers Fail

Danger Present

There is an immediate risk of electric shock or fire right now—for example, a smashed socket faceplate with live brass pins exposed. An electrician will usually make a C1 safe or isolate that specific circuit before leaving your property on the day of the test.

Code C2 Triggers Fail

Potentially Dangerous

Not immediately lethal if nobody touches it, but would become dangerous if a fault occurred. Common examples include missing earth connections on metal light fittings, no RCD protection on sockets that could be used outdoors, or overheated connections inside the fuse board.

Code FI Triggers Fail

Further Investigation Required

Our test meter has picked up a strange or unsafe reading—such as low insulation resistance or a mysterious circuit wired into a breaker—that we can’t trace without taking up floorboards or dismantling fittings. Because it could be hiding a C1 or C2 fault, an FI always makes the report Unsatisfactory.

Code C3 Still a Pass

Improvement Recommended

The installation doesn’t meet the very latest edition of the wiring regulations, but it is still safe to use (for example, an older plastic consumer unit in good condition in an upstairs flat). You can have ten C3 codes and your EICR will still be Satisfactory.

The 28-Day Rule: What Landlords Legally Have to Do

If you own and live in your own home, an Unsatisfactory EICR is for your own safety—or to satisfy a mortgage lender or buyer if you are selling. Nobody is going to fine you if you take six weeks to book the repairs, though obviously we advise sorting C1 and C2 items quickly so your family isn’t at risk.

For private landlords, the rules under the Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020 are strict:

1

Complete C1, C2 & FI repairs within 28 days

From the date of the inspection, you have a maximum of 28 days to have a qualified electrician investigate any FI codes and fix all C1 and C2 faults. If the report specifies a shorter deadline for an urgent hazard, you must stick to that shorter timeframe.

2

Get written confirmation from the electrician

Once the remedial work is finished, the electrician must give you written confirmation (usually an Electrical Installation Certificate or Minor Electrical Installation Works Certificate) stating that the faults identified on the EICR have been put right.

3

Send copies to your tenants and the council (within 28 days of the repair)

You must supply a copy of the written confirmation—alongside the original Unsatisfactory EICR—to your tenant within 28 days of the repairs being completed. You must also send both documents to the local housing authority within that same 28-day window if the report was originally Unsatisfactory.

Do You Have to Pay for a Brand-New EICR After Repairs?

No—and don’t let anyone tell you otherwise. One of the biggest misconceptions we come across is landlords or homeowners thinking they need to pay for a second full EICR to get a piece of paper that says “Satisfactory” at the top.

Once an EICR is issued as Unsatisfactory, that original report is a snapshot of how the electrics looked on that specific day; an electrician shouldn’t go back and rewrite history on the original PDF. Instead, the legal and industry-standard way it works is by pairing two documents together:

Document 1

The Original EICR

This shows that the whole house was tested and lists the exact items (for example, Observation 1: C2 – No RCD protection on ground floor sockets; Observation 2: C2 – Broken socket in back bedroom) that caused the failure.

Document 2

Remedial Certificate (EIC or MEIWC)

When we carry out the repairs, we test the circuits we’ve worked on and issue an Electrical Installation Certificate (EIC) (for example, if we upgraded the consumer unit) or a Minor Electrical Installation Works Certificate (MEIWC) referencing the original EICR report number.

Keep those two documents stapled together (or saved in the same folder). Together, they prove to your letting agent, tenant, insurer, or local council that the property was inspected, all C1/C2/FI defects were fixed, and the installation is now compliant for the next 5 years (or until the date stated on the report).

Newly installed FuseBox consumer unit upgrade with surge protection and labeled circuit breakers
Common Remedial Upgrade

What Typical EICR Remedial Work Looks Like

Many Unsatisfactory EICRs come down to outdated fuse boards lacking RCD protection, missing main protective bonding to the gas or water incoming pipes, or DIY alterations where earths were left disconnected.

In many properties, upgrading the consumer unit to a modern metal unit with individual RCBO breakers and fixing a handful of accessories clears every C2 fault in a single day’s work.

Do You Have to Use the Same Electrician for the Repairs?

No. You are under no obligation to use the company that carried out the inspection to do the remedial work.

Sometimes we get calls from landlords or homeowners who have had a very cheap inspection done by a national call-centre firm, only to be handed a much larger quote for remedial works that includes charging for harmless C3 items or replacing a fuse board that only needed a single RCBO fitted. Typical costs vary widely depending on the installation.

If you have an Unsatisfactory EICR from another contractor and want an honest second opinion—or a straightforward quote to fix only the genuine C1, C2, and FI items required to pass—just send a copy of the report over to us. We will read through the test schedule, tell you in plain English what actually needs doing, and issue the sign-off certificates once the repairs are complete.

What If an EICR Fails During a House Sale?

When a homebuyer books an EICR before exchanging contracts, an Unsatisfactory result rarely kills the sale—it just gives everyone clarity on what they are buying.

  • Minor C2 faults (damaged sockets, lack of bonding, non-fire-rated bathroom lights): Usually cost a few hundred pounds to put right. Either the seller agrees to have them fixed before completion, or the buyer simply budgets to have them sorted once they get the keys.
  • Outdated fuse board (no RCD protection): A consumer unit upgrade typically takes a day, includes full circuit testing and Building Regulations notification, and immediately brings the heart of the installation up to modern safety standards.
  • Perished cabling or rubber/VIR wiring: If the insulation resistance tests show the cables hidden in the walls have broken down with age, the property may need a partial or full house rewire. Knowing this before you exchange allows you to negotiate fairly on the purchase price with a proper written quote in hand.
Further Reading & Electrical Services

Related Services & Guides

Electrical Inspections & EICR Certificates in Bristol

Expert EICR certificates and electrical safety inspections in Bristol, also covering Keynsham, Bath and BS31. Fast reports for landlords and homebuyers. Book your inspection today.

Read More

What Size Solar Battery Do I Need for My Home?

Work out the right kWh solar battery capacity for your home based on your daily electricity use, solar panel size, and overnight energy tariffs.

Read More

How Much Does It Cost to Install a Home EV Charger?

Find out realistic UK costs for installing a home EV charger, and see how cable runs, fuse board space, and OZEV grants affect your final quote.

Read More

How Long Does a Fuse Box Replacement Take?

Find out what happens during a consumer unit upgrade, how long your power will be off, and how we handle wiring faults and Part P sign-off.

Read More

How to Prepare Your Property for an EICR Test

Use our simple EICR preparation checklist to get your home or rental ready. Learn how to clear access to your fuse board and sockets to avoid delays.

Read More

How Do You Know if Your House Needs Rewiring?

Learn how to spot the telltale signs of outdated wiring, from old rewireable fuses and black rubber cables to sockets in skirting boards and green goo.

Read More

How Often Do Businesses Need a Commercial EICR?

Find out how often your UK business needs a commercial EICR. We explain legal duties, testing intervals for offices and shops, and how inspections are planned.

Read More

Why Does My Fuse Box Keep Tripping?

Find out why your fuse box or RCD keeps tripping. Learn how to safely check for faulty appliances like kettles and when to call a qualified electrician.

Read More

Do You Need Planning Permission for Solar Panels?

Most UK homes don't need planning permission for solar panels. Learn how permitted development, conservation areas, and building regs apply to your roof.

Read More

Tethered vs Untethered EV Chargers: Which Is Best?

Compare fixed-cable convenience with socket-only neatness. Find out whether a tethered or untethered EV charger suits your home and driving habits best.

Read More

Do I Need Surge Protection on My Fuse Board?

Learn what a Surge Protection Device (SPD) does, why 18th Edition rules require them, and how they protect your boiler, EV charger, and appliances.

Read More

What Is First Fix and Second Fix Electrics?

Learn the difference between first and second fix electrics so you can plan your home rewire around plasterers, kitchen fitters, and decorators.

Read More

Is Upgrading Office and Shop Lighting to LED Worth It?

Find out how much replacing old fluorescent tubes with commercial LED panels and sensors can cut your energy bills, and what to expect during installation.

Read More

Need EICR Remedial Works Completed Quickly?

Speak directly to an experienced electrician at Briggs Bray Electrical Services Ltd. We can review your existing EICR, carry out any required C1, C2, or FI repairs, and issue your compliance certificates without delay.